Anodized Aluminum Nosing: 9064

Product Category: IBC Path Marking

The current IBC Code requirements for Photoluminescent markings in high-rise buildings are in large part taken from the NYC Reference Standard 6-1 (RS6-1). So you can be assured that Jalite products meet the code, because we helped write the code.

Code

Product Number: 9064

1024.2.1 Steps. A solid and continuous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step. Outlining stripes shall have a minimum horizontal width of 1 inch (25 mm) and a maximum width of 2 inches (51 mm). The leading edge of the stripe shall be placed at a maximum of 1/2 inch (12.7 mm) from the leading edge of the step and the stripe shall overlap the leading edge of the step by not more than 1/2 inch (12.7 mm) down the vertical face of the step.

1024.2.2 Landings. The leading edge of landings shall be marked with a stripe consistent with the dimensional requirements for steps.

Usage

The IBC requires that the perimeter of each landing in the stairwell and any horizontal corridor in the exit enclosure be marked. The Jalite solution is easy to install with proven durability. Jalite provides you with several attractive and proven solutions.